Power & Mains Transformers

Reset All
Part RoHS Manufacturer Transformer Type Mounting Feature Manufacturer Series Approvals (V) Terminal Finish Power Rating Center Tap Feature-2 No. of Functions No. of Winding (Primary) Isolation Voltage Inductance (Primary) Packing Method Output Current-1 Minimum ET Product Output Current-2 No. of Winding (Secondary) Sub-Category Dimensions Volt-Ampere Rating (VA) Maximum Operating Temperature Center Tap Feature-1 Application Output Voltage-2 Output Voltage-1 Minimum Operating Temperature Nominal Operating Frequency Rating (Primary) Height Width Diameter Nominal Input Voltage (V) Load Resistance Additional Features Minimum Input Voltage (V) JESD-609 Code Minimum Operating Frequency Length Turns Ratio (Np:Ns) Maximum Operating Frequency Maximum Input Voltage (V)

1085

Amecon

TOROIDAL POWER TRANSFORMER

1.25 A

1

30 VA

60 HZ

2288

Amecon

TOROIDAL POWER TRANSFORMER

2288

10-6

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

YES

1500 V

6 A

6 A

2

L85.7XB69.9XH71.4 (mm)

YES

5 V

5 V

50/60 HZ

SINGLE 115V

71.4 mm

69.9 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

85.7 mm

F-261U

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

8 A

1

Other Transformers

L87.3XB88.9XH104.77 (mm)

192 VA

YES

POWER

24 V

50/60 HZ

SINGLE 115V

104.77 mm

88.9 mm

87.3 mm

115

2267

Amecon

TOROIDAL POWER TRANSFORMER

2267

3.48 A

1

400 VA

60 HZ

F-16X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

2500 V

3 A

1

Other Transformers

L84.12XB50.8XH49.2 (mm)

18.9 VA

YES

POWER

6.3 V

50/60 HZ

SINGLE 115V

49.2 mm

50.8 mm

84.12 mm

115

MA5632-ALB

Coilcraft

POWER TRANSFORMER

SURFACE MOUNT

Tin/Silver (Sn/Ag)

NO

2500 V

TR

2

Other Transformers

12.07mm x 8.1mm x 5.97mm

125 Cel

NO

3.3 V

5 V

-40 Cel

DUAL 3.3-5V

5.97 mm

8.1 mm

e2

10.3 mm

F-44X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

1.5 A

1

Other Transformers

L101.6XB57.15XH65.86 (mm)

25.2 VA

YES

POWER

35 V

50/60 HZ

SINGLE 115V

65.86 mm

57.15 mm

101.6 mm

115

1121

Amecon

TOROIDAL POWER TRANSFORMER

8.33 A

1

75 VA

60 HZ

MA5632-ALD

Coilcraft

POWER TRANSFORMER

SURFACE MOUNT

Tin/Silver - Matte Tin - with Nickel barrier

NO

2500 V

TR, EMBOSSED PLASTIC, 13 INCH

2

Other Transformers

12.07mm x 8.1mm x 5.97mm

125 Cel

NO

3.3 V

5 V

-40 Cel

DUAL 3.3-5V

5.97 mm

8.1 mm

10.3 mm

1143

Amecon

TOROIDAL POWER TRANSFORMER

6.67 A

1

100 VA

60 HZ

F-118X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

.7 A

1

Other Transformers

L82.55XB50.8XH50.8 (mm)

16.8 VA

YES

POWER

24 V

50/60 HZ

SINGLE 115V

50.8 mm

50.8 mm

82.55 mm

115

68-4

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

68

YES

1500 V

4 A

4 A

2

114.3mm X 114.3mm X 95.3mm

YES

34 V

34 V

50/60 HZ

SINGLE 115V

95.3 mm

114.3 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

114.3 mm

10-25

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

YES

1500 V

50 A

25 A

2

L114.3XB95.3XH95.3 (mm)

YES

5 V

5 V

50/60 HZ

SINGLE 115V

95.3 mm

95.3 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

114.3 mm

1047

Amecon

TOROIDAL POWER TRANSFORMER

.83 A

1

15 VA

60 HZ

F-341X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

2

1500 V

2 A

1

Other Transformers

L101.6XB57.15XH65.86 (mm)

50.4 VA

YES

POWER

25.2 V

50/60 HZ

SINGLE 115/230V

65.86 mm

57.15 mm

101.6 mm

1142

Amecon

TOROIDAL POWER TRANSFORMER

8.33 A

1

100 VA

60 HZ

FP24-500

Triad Magnetics

SPLIT BOBBIN POWER TRANSFORMER

THROUGH HOLE MOUNTED

UL

NO

2

2000 V

1 A

1 A

2

L63.5XB50.8XH26.97 (mm)

12 VA

NO

POWER

12 V

12 V

50/60 HZ

DUAL 115/230V

26.97 mm

50.8 mm

115/230

PCB MOUNTABLE

63.5 mm

732

Hammond Manufacturing

POWER TRANSFORMER

CHASSIS MOUNT

CSA

NO

1

500 VA

YES

2500 V

50/60 HZ

SINGLE 115V

115

115

1082

Amecon

TOROIDAL POWER TRANSFORMER

2.5 A

1

30 VA

60 HZ

1317

Amecon

TOROIDAL POWER TRANSFORMER

13.04 A

1

1500 VA

60 HZ

739

Hammond Manufacturing

POWER TRANSFORMER

CHASSIS MOUNT

CSA

NO

1

1610 VA

YES

3500 V

50/60 HZ

SINGLE 115V

115

115

10-12

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

YES

1500 V

12 A

12 A

2

L95.3XB82.6XH79.4 (mm)

YES

5 V

5 V

50/60 HZ

SINGLE 115V

79.4 mm

82.6 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

95.3 mm

1112

Amecon

TOROIDAL POWER TRANSFORMER

1.04 A

1

50 VA

60 HZ

16-12

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

16

YES

1500 V

12 A

12 A

2

104.8mm X 98.4mm X 87.3mm

YES

8 V

8 V

50/60 HZ

SINGLE 115V

87.3 mm

98.4 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

104.8 mm

SIM800

Block Transformatoren-elektronik

POWER TRANSFORMER

CHASSIS MOUNT

CUL; EAC; UL; VDE

NO

2

800 VA

40 Cel

NO

12 V

12 V

50-60 HZ

SINGLE 230V

166.116 mm

199.898 mm

230

282.956 mm

1326

Amecon

TOROIDAL POWER TRANSFORMER

6.52 A

1

1500 VA

60 HZ

1089

Amecon

TOROIDAL POWER TRANSFORMER

1 A

1

30 VA

60 HZ

1195

Amecon

TOROIDAL POWER TRANSFORMER

1.3 A

1

150 VA

60 HZ

36-1

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

36

YES

1500 V

1 A

1 A

2

76.2mm X 69.9mm X 63.5mm

YES

18 V

18 V

50/60 HZ

SINGLE 115V

63.5 mm

69.9 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

76.2 mm

36-2

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

YES

1500 V

2 A

2 A

2

85.7mm X 74.6mm X 71.4mm

YES

18 V

18 V

50/60 HZ

SINGLE 115V

71.4 mm

74.5 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

85.7 mm

1193

Amecon

TOROIDAL POWER TRANSFORMER

2.68 A

1

150 VA

60 HZ

44272

Myrra Sas

POWER TRANSFORMER

THROUGH HOLE MOUNTED

EN; UL

NO

.556 A

2

10 VA

50 Cel

NO

9 V

9 V

50-60 HZ

SINGLE 230V

34.75 mm

42.5 mm

230

50.5 mm

1110

Amecon

TOROIDAL POWER TRANSFORMER

1.67 A

1

50 VA

60 HZ

56-25

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

56

YES

1500 V

25 A

25 A

2

162mm X 181mm X 134.9mm

YES

28 V

28 V

50/60 HZ

SINGLE 105/115/125V

134.9 mm

181 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

162 mm

1049

Amecon

TOROIDAL POWER TRANSFORMER

.5 A

1

15 VA

60 HZ

36-4

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

36

YES

1500 V

4 A

4 A

2

104.8mm X 85.7mm X 87.3mm

YES

18 V

18 V

50/60 HZ

SINGLE 115V

87.3 mm

85.7 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

104.8 mm

F-219X

Triad Magnetics

POWER TRANSFORMER

CHASSIS MOUNT

UL

NO

1

1500 V

4 A

1

Other Transformers

L101.6XB57.15XH65.07 (mm)

NO

POWER

12 V

60 HZ

SINGLE 115V

65.07 mm

57.15 mm

101.6 mm

115

1191

Amecon

TOROIDAL POWER TRANSFORMER

4.17 A

1

150 VA

60 HZ

56-12

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

YES

1500 V

12 A

12 A

2

L162XB133.4XH134.9 (mm)

YES

28 V

28 V

50/60 HZ

SINGLE 105/115/125V

134.9 mm

133.4 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

162 mm

1115

Amecon

TOROIDAL POWER TRANSFORMER

.43 A

1

50 VA

60 HZ

DA2303-ALD

Coilcraft

POWER TRANSFORMER

SURFACE MOUNT

AEC-Q200

Tin/Silver - Tin - with Nickel barrier

NO

2500 V

TR, EMBOSSED PLASTIC, 13 INCH

2

L12.07XB10.0XH5.97 (mm)

125 Cel

NO

6 V

6 V

-40 Cel

150 KHZ

DUAL 5V

5.97 mm

8.1 mm

5

10.3 mm

44274

Myrra Sas

POWER TRANSFORMER

THROUGH HOLE MOUNTED

EN; UL

NO

.333 A

2

10 VA

50 Cel

NO

15 V

15 V

50-60 HZ

SINGLE 230V

34.75 mm

42.5 mm

230

50.5 mm

10-8

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

YES

1500 V

8 A

8 A

2

L85.7XB79.4XH71.4 (mm)

YES

5 V

5 V

50/60 HZ

SINGLE 115V

71.4 mm

79.4 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

85.7 mm

1192

Amecon

TOROIDAL POWER TRANSFORMER

3.13 A

1

150 VA

60 HZ

10-4

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

YES

1500 V

4 A

4 A

2

L90.5XB60.3XH77.7 (mm)

YES

5 V

5 V

50/60 HZ

SINGLE 115V

77.7 mm

60.3 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

90.5 mm

1164

Amecon

TOROIDAL POWER TRANSFORMER

6.67 A

1

120 VA

60 HZ

2107

Amecon

TOROIDAL POWER TRANSFORMER

2107

.35 A

1

40 VA

60 HZ

Power & Mains Transformers

Power and mains transformers are types of electrical transformers used in power transmission and distribution systems to convert high voltage and low current to low voltage and high current or vice versa. They are essential components in the electricity grid, and are used to step up or step down voltage levels for efficient transmission and distribution of electrical energy.

Power transformers are used in high voltage transmission systems, typically at voltages of 110 kV and above, to step up or step down the voltage levels. They have a high power rating, typically ranging from several hundred kVA to several thousand MVA, and are designed to handle high currents and voltages without overheating or breaking down. Power transformers are typically oil-immersed, and use a magnetic core made of laminated steel to reduce losses and improve efficiency.

Mains transformers, also known as distribution transformers, are used in low voltage distribution systems, typically at voltages of 11 kV or below, to step down the voltage levels for use by consumers. They have a lower power rating than power transformers, typically ranging from several kVA to several hundred kVA, and are designed to operate at lower voltages and currents. Mains transformers are typically dry-type, and use a magnetic core made of laminated steel or ferrite to reduce losses and improve efficiency.

Both power and mains transformers require proper design, selection, and maintenance to ensure reliable and efficient operation. They are subject to various standards and regulations, such as IEC (International Electrotechnical Commission) and IEEE (Institute of Electrical and Electronics Engineers), to ensure their safety and performance. Proper installation and maintenance of transformers, such as regular inspection, testing, and oil analysis, are also critical to ensure their longevity and performance.