Power & Mains Transformers

Reset All
Part RoHS Manufacturer Transformer Type Mounting Feature Manufacturer Series Approvals (V) Terminal Finish Power Rating Center Tap Feature-2 No. of Functions No. of Winding (Primary) Isolation Voltage Inductance (Primary) Packing Method Output Current-1 Minimum ET Product Output Current-2 No. of Winding (Secondary) Sub-Category Dimensions Volt-Ampere Rating (VA) Maximum Operating Temperature Center Tap Feature-1 Application Output Voltage-2 Output Voltage-1 Minimum Operating Temperature Nominal Operating Frequency Rating (Primary) Height Width Diameter Nominal Input Voltage (V) Load Resistance Additional Features Minimum Input Voltage (V) JESD-609 Code Minimum Operating Frequency Length Turns Ratio (Np:Ns) Maximum Operating Frequency Maximum Input Voltage (V)

VPS24-7300

Triad Magnetics

SPLIT BOBBIN POWER TRANSFORMER

CHASSIS MOUNT

CUL; CSA,TUV, UL

YES

2

4000 V

14.6 A

14.6 A

2

L79.38XB71.42XH85.72 (mm)

175 VA

YES

POWER

12 V

12 V

50/60 HZ

DUAL 115V

85.72 mm

71.42 mm

115/230

79.38 mm

VTX-120-003-606

Vigortronix Uk

POWER TRANSFORMER

THROUGH HOLE MOUNTED

CE

NO

4200 V

.25 A

2

3 VA

NO

6 V

6 V

50/60 HZ

DUAL 120V

30 mm

32 mm

120/240

38 mm

VTX-120-003-609

Vigortronix Uk

POWER TRANSFORMER

THROUGH HOLE MOUNTED

CE

NO

4200 V

.166 A

2

3 VA

NO

9 V

9 V

50/60 HZ

DUAL 120V

30 mm

32 mm

120/240

38 mm

1.182E+113

Hammond Manufacturing

TOROIDAL POWER TRANSFORMER

1146

Amecon

TOROIDAL POWER TRANSFORMER

3.57 A

1

100 VA

60 HZ

1182H110

Hammond Manufacturing

TOROIDAL POWER TRANSFORMER

CHASSIS MOUNT

CE; CSA; IEC; UL

NO

4000 V

.728 A

2

80 VA

NO

110 V

110 V

50/60 HZ

DUAL 117/234V

38.1 mm

88.9 mm

117/234

4000-09AW18AE999

TE Connectivity

POWER TRANSFORMER

CHASIS MOUNT

BULK

50 VA

24 V

208/240

45024

Myrra Sas

POWER TRANSFORMER

THROUGH HOLE MOUNTED

CSA, UL, VDE

NO

4000 V

.083 A

.083 A

2

4 VA

70 Cel

NO

24 V

24 V

DUAL 115V

19 mm

44 mm

115

PARALLEL CONNECTED

53 mm

FL24/12

Block Transformatoren-elektronik

POWER TRANSFORMER

THROUGH HOLE MOUNTED

CSA; CUL; EAC; UL; VDE

NO

2

24 VA

40 Cel

NO

12 V

12 V

50/60 HZ

DUAL 115V

31.496 mm

56.896 mm

115

68.072 mm

VPT30-3330

Triad Magnetics

TOROIDAL POWER TRANSFORMER

CHASSIS MOUNT

CE, CUL, UL

TIN

NO

2

4000 V

6.66 A

6.66 A

2

D87.0XH47.0 (mm)

100 VA

NO

POWER

15 V

15 V

50/60 HZ

DUAL 115V

51 mm

88 mm

115/230

e3

VTX-120-003-612

Vigortronix Uk

POWER TRANSFORMER

THROUGH HOLE MOUNTED

CE

NO

4200 V

.125 A

2

3 VA

NO

12 V

12 V

50/60 HZ

DUAL 120V

30 mm

32 mm

120/240

38 mm

1182M110

Hammond Manufacturing

TOROIDAL POWER TRANSFORMER

CHASSIS MOUNT

CE; CSA; IEC; UL

NO

4000 V

2.72 A

2

300 VA

NO

110 V

110 V

50/60 HZ

DUAL 117/234V

50.8 mm

127 mm

117/234

1182Q110

Hammond Manufacturing

TOROIDAL POWER TRANSFORMER

CHASSIS MOUNT

CE; CSA; IEC; UL

NO

4000 V

5.68 A

2

625 VA

NO

110 V

110 V

50/60 HZ

DUAL 117/234V

60.452 mm

149.352 mm

117/234

2025

Amecon

TOROIDAL POWER TRANSFORMER

2025

.33 A

1

8 VA

60 HZ

2243

Amecon

TOROIDAL POWER TRANSFORMER

2243

21.33 A

1

320 VA

60 HZ

44087

Myrra Sas

POWER TRANSFORMER

THROUGH HOLE MOUNTED

CE; CSA; IEC; VDE; UL

NO

1

1.5 VA

70 Cel

NO

12 V

-25 Cel

50/60 HZ

SINGLE 230V

23.8 mm

26.7 mm

230

31.7 mm

4781-01

Api Technologies

POWER TRANSFORMER

CHASSIS MOUNT

4781

NO

8 A

1

L76.2XB63.5XH66.04 (mm)

450 VA

NO

5 V

60 HZ

SINGLE 115V

66.04 mm

63.5 mm

76.2 mm

56-2

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

56

YES

1500 V

2 A

2 A

2

95.3mm X 82.6mm X 79.4mm

YES

28 V

28 V

50/60 HZ

SINGLE 115V

79.4 mm

82.6 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

95.3 mm

PH100QR

Hammond Power Solutions

POWER TRANSFORMER

CHASSIS MOUNT

CE, CUL

NO

8.33 A

4.17 A

2

100 VA

NO

24 V

12 V

60 HZ

DUAL 240/480V

3.63 mm

3.25 mm

240/480

4.19 mm

PH150QR

Hammond Power Solutions

POWER TRANSFORMER

CHASSIS MOUNT

CE, CUL

NO

12.5 A

6.25 A

2

150 VA

NO

24 V

12 V

60 HZ

DUAL 240/480V

3.81 mm

4 mm

240/480

4.94 mm

PH250MLI

Hammond Power Solutions

POWER TRANSFORMER

CHASSIS MOUNT

CE, CUL

NO

2.17 A

10.42 A

2

250 VA

NO

25 V

120 V

60 HZ

DUAL 240/480V

4.44 mm

4.5 mm

480/240

5.19 mm

PH75QR

Hammond Power Solutions

POWER TRANSFORMER

CHASSIS MOUNT

CE, CUL

NO

6.25 A

3.13 A

2

75 VA

NO

24 V

12 V

60 HZ

DUAL 240/480V

3.56 mm

3.25 mm

240/480

3.88 mm

SIM300

Block Transformatoren-elektronik

POWER TRANSFORMER

CHASSIS MOUNT

EAC, VDE

NO

2

300 VA

40 Cel

NO

12 V

12 V

50/60 HZ

SINGLE 230V

117.094 mm

117.094 mm

230

223.012 mm

T-2-53011-S

Acme Electric

POWER TRANSFORMER

UL; CSA

1

1500 VA

60 HZ

VCM36/2/24

Block Transformatoren-elektronik

POWER TRANSFORMER

THROUGH HOLE MOUNTED

CSA; CUL; EAC; UL; VDE

NO

2

36 VA

40 Cel

NO

24 V

24 V

50-60 HZ

SINGLE 230V

48.514 mm

60.96 mm

230

87.122 mm

VPT30-5330

Triad Magnetics

TOROIDAL POWER TRANSFORMER

CHASSIS MOUNT

CE, CUL, UL

TIN

NO

2

4000 V

8.88 A

8.88 A

2

D103.0XH48.0 (mm)

160 VA

NO

POWER

18 V

18 V

50/60 HZ

DUAL 115V

52 mm

106 mm

115/230

e3

VTX-120-4206-209

Vigortronix Uk

POWER TRANSFORMER

THROUGH HOLE MOUNTED

CE

NO

4200 V

.333 A

2

6 VA

NO

9 V

9 V

50/60 HZ

SINGLE 230V

32 mm

36 mm

230

43 mm

VTX-146-500-135

Multicomp Pro

TOROIDAL POWER TRANSFORMER

CHASSIS MOUNT

NO

7.14 A

7.14 A

2

D135.0XH59.0 (mm)

500 VA

NO

35 V

35 V

SINGLE 230V

59 mm

135 mm

1182K110

Hammond Manufacturing

TOROIDAL POWER TRANSFORMER

CHASSIS MOUNT

CE; CSA; IEC; UL

NO

4000 V

1.45 A

2

160 VA

NO

110 V

110 V

50/60 HZ

DUAL 117/234V

44.45 mm

107.95 mm

117/234

1182L110

Hammond Manufacturing

TOROIDAL POWER TRANSFORMER

CHASSIS MOUNT

CE; CSA; IEC; UL

NO

4000 V

2.04 A

2

225 VA

NO

110 V

110 V

50/60 HZ

DUAL 117/234V

50.8 mm

114.3 mm

117/234

2044

Amecon

TOROIDAL POWER TRANSFORMER

2044

.67 A

1

12 VA

60 HZ

2129

Amecon

TOROIDAL POWER TRANSFORMER

2129

2.5 A

1

60 VA

60 HZ

24-4

Bel Fuse

POWER TRANSFORMER

CHASSIS MOUNT

24

YES

1500 V

4 A

4 A

2

95.3mm X 79.4mm X 79.4mm

YES

12 V

12 V

50/60 HZ

SINGLE 115V

79.4 mm

79.4 mm

THE TWO SECONDARIES HAVE CENTER TAPPED CONNECTIONS

95.3 mm

278X

Hammond Manufacturing

POWER TRANSFORMER

CHASSIS MOUNT

CSA

YES

2000 V

6 A

.23 A

3

229 VA

YES

6.3 V

800 V

60 HZ

SINGLE 115V

96.774 mm

79.502 mm

115

101.6 mm

AVB3,2/2/18

Block Transformatoren-elektronik

POWER TRANSFORMER

THROUGH HOLE MOUNTED

CSA, CUL, EAC

NO

2

3.2 VA

50 Cel

NO

18 V

18 V

50-60 HZ

DUAL 115V

30.8 mm

35 mm

115

41 mm

CTPTF-7801EP13

Central Technologies

POWER TRANSFORMER

SURFACE MOUNT

NO

1500 V

.02 A

2

125 Cel

NO

3.3 V

12 V

-40 Cel

200 KHZ

SINGLE 33-57V

13 mm

14 mm

LENGTH AND HEIGHT DIMENSION INCLUDE TERMINAL ALSO

17.5 mm

DSW-412

Stancor Products

POWER TRANSFORMER

DSW

UL; CSA

.5 A

1

6 VA

105 Cel

-40 Cel

60 HZ

PCB MOUNTABLE

DSW-4120

Stancor Products

POWER TRANSFORMER

DSW

UL; CSA

.05 A

1

6 VA

105 Cel

-40 Cel

60 HZ

PCB MOUNTABLE

VB0,5/2/8

Block Transformatoren-elektronik

POWER TRANSFORMER

THROUGH HOLE MOUNTED

CSA; CUL; EAC; UL; VDE

NO

2

.5 VA

70 Cel

NO

8 V

8 V

50-60 HZ

SINGLE 230V

19 mm

22 mm

230

22.7 mm

VPS28-900

Triad Magnetics

SPLIT BOBBIN POWER TRANSFORMER

CHASSIS MOUNT

CE, CSA, CUL, TUV, UL

NO

2

4000 V

1.8 A

1.8 A

2

L71.42XB49.2XH58.72 (mm)

25 VA

NO

POWER

14 V

14 V

50/60 HZ

DUAL 115V

58.72 mm

49.2 mm

115/230

71.42 mm

VTX-120-4206-406

Vigortronix Uk

POWER TRANSFORMER

THROUGH HOLE MOUNTED

CE

NO

4200 V

.5 A

2

6 VA

NO

6 V

6 V

50/60 HZ

DUAL 115V

32 mm

36 mm

115/230

43 mm

45003

Myrra Sas

POWER TRANSFORMER

THROUGH HOLE MOUNTED

CSA, UL, VDE

NO

4000 V

.083 A

1

1 VA

70 Cel

NO

12 V

SINGLE 230V

15 mm

31 mm

230

34 mm

45039

Myrra Sas

POWER TRANSFORMER

THROUGH HOLE MOUNTED

UL

NO

4000 V

.416 A

.416 A

2

10 VA

50 Cel

NO

12 V

12 V

DUAL 115V

22 mm

57 mm

115

PARALLEL CONNECTED

68 mm

BVEI5411209

Hahn And Kg

POWER TRANSFORMER

THROUGH HOLE MOUNTED

NO

1

16 VA

NO

15 V

50-60 HZ

SINGLE 230V

38.8 mm

47.3 mm

230

56.4 mm

F10-110

Triad Magnetics

SPLIT BOBBIN POWER TRANSFORMER

THROUGH HOLE MOUNTED

CSA, UL

YES

1

2500 V

.22 A

.22 A

2

L34.92XB28.57XH23.8 (mm)

1.1 VA

YES

POWER

5 V

5 V

50/60 HZ

SINGLE 115V

23.8 mm

28.57 mm

115

34.92 mm

FL52/15

Block Transformatoren-elektronik

POWER TRANSFORMER

THROUGH HOLE MOUNTED

CSA; CUL; EAC; UL; VDE

NO

2

52 VA

40 Cel

NO

15 V

15 V

50/60 HZ

DUAL 115V

49.022 mm

70.104 mm

115

86.614 mm

FS12-090-C2

Triad Magnetics

SPLIT BOBBIN POWER TRANSFORMER

THROUGH HOLE MOUNTED

CE; CUL; TUV; UL

NO

4200 V

.09 A

2

1.1 VA

115 Cel

NO

6.3 V

6.3 V

-40 Cel

50/60 HZ

DUAL 115V

25.4 mm

30.51 mm

115/230

35.99 mm

VTX-120-4206-415

Vigortronix Uk

POWER TRANSFORMER

THROUGH HOLE MOUNTED

CE

NO

4200 V

.2 A

2

6 VA

NO

15 V

15 V

50/60 HZ

DUAL 115V

32 mm

36 mm

115/230

43 mm

Power & Mains Transformers

Power and mains transformers are types of electrical transformers used in power transmission and distribution systems to convert high voltage and low current to low voltage and high current or vice versa. They are essential components in the electricity grid, and are used to step up or step down voltage levels for efficient transmission and distribution of electrical energy.

Power transformers are used in high voltage transmission systems, typically at voltages of 110 kV and above, to step up or step down the voltage levels. They have a high power rating, typically ranging from several hundred kVA to several thousand MVA, and are designed to handle high currents and voltages without overheating or breaking down. Power transformers are typically oil-immersed, and use a magnetic core made of laminated steel to reduce losses and improve efficiency.

Mains transformers, also known as distribution transformers, are used in low voltage distribution systems, typically at voltages of 11 kV or below, to step down the voltage levels for use by consumers. They have a lower power rating than power transformers, typically ranging from several kVA to several hundred kVA, and are designed to operate at lower voltages and currents. Mains transformers are typically dry-type, and use a magnetic core made of laminated steel or ferrite to reduce losses and improve efficiency.

Both power and mains transformers require proper design, selection, and maintenance to ensure reliable and efficient operation. They are subject to various standards and regulations, such as IEC (International Electrotechnical Commission) and IEEE (Institute of Electrical and Electronics Engineers), to ensure their safety and performance. Proper installation and maintenance of transformers, such as regular inspection, testing, and oil analysis, are also critical to ensure their longevity and performance.