Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Actuator Type | Packing Method | Body Length/Diameter | Body Width | Environmental Characteristics | JESD-609 Code | Dimensions | Circuit Function | Body Height | Reference Standard | No. of Poles | Maximum Operating Temperature | Blow Characteristic |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Abb |
THERMAL MAGNETIC |
||||||||||||||||||||||||||
|
TE Connectivity |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
250 V |
32 V |
8 A |
QUICK CONNECT |
1000 A |
2.2 Seconds |
PUSH TO RESET |
15.88 mm |
13.72 inch |
15.88mm x 13.72mm x 38.99mm |
SERIES TRIP |
38.99 mm |
CSA; UL; VDE |
1 |
||||||||||
Abb |
THERMAL MAGNETIC |
||||||||||||||||||||||||||
Legrand |
THERMAL CIRCUIT BREAKER |
DIN-RAIL MOUNT |
400 V |
40 A |
SNAP ON |
-25 Cel |
50000 A |
HANDLE |
BULK |
165 mm |
105 inch |
TRIP |
100 mm |
IEC |
3 |
70 Cel |
|||||||||||
TE Connectivity |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
250 V |
32 V |
20 A |
QUICK CONNECT |
1000 A |
2.2 Seconds |
PUSH TO RESET |
15.88 mm |
13.72 inch |
15.88mm x 13.72mm x 38.99mm |
SERIES TRIP |
38.99 mm |
CSA; SEV; UL; VDE |
1 |
|||||||||||
TE Connectivity |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
250 V |
32 V |
20 A |
QUICK CONNECT |
2.2 Seconds |
PUSH TO RESET |
SERIES TRIP |
1 |
|||||||||||||||||
TE Connectivity |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
250 V |
32 V |
20 A |
QUICK CONNECT |
2.2 Seconds |
PUSH TO RESET |
SERIES TRIP |
1 |
|||||||||||||||||
|
TE Connectivity |
MAGNETIC CIRCUIT BREAKER |
PANEL MOUNT |
277 V |
30 A |
STUD |
-40 Cel |
5000 A |
2.2 Seconds |
TOGGLE |
63.5 mm |
57.15 inch |
SERIES TRIP |
46.86 mm |
3 |
85 Cel |
|||||||||||
|
Schneider Electric Sa |
THERMAL MAGNETIC |
|||||||||||||||||||||||||
|
TE Connectivity |
MAGNETIC CIRCUIT BREAKER |
PANEL MOUNT |
277 V |
20 A |
QUICK CONNECT |
-40 Cel |
5000 A |
2.2 Seconds |
TOGGLE |
50.8 mm |
38.1 inch |
FUNGUS RESISTANT; MOISTURE RESISTANT |
50.8mm x 38.1mm x 41.66mm |
SERIES TRIP |
41.66 mm |
CSA; UL |
2 |
85 Cel |
STANDARD |
|||||||
|
Abb |
THERMAL MAGNETIC |
|||||||||||||||||||||||||
|
Schneider Electric Sa |
THERMAL MAGNETIC CIRCUIT BREAKER |
PANEL MOUNT/DIN-RAIL MOUNT |
690 V |
50 A |
SCREW AND SNAP ON |
-20 Cel |
6000 A |
REFERENCE STANDARD: UL |
ROTARY HANDLE |
BULK |
132 mm |
55 inch |
IK09; IP20 |
TRIP |
136 mm |
ABS; ATEX; BV; CSA; CCC; DNV-GL; EAC; EN; IEC; LR0S; UKCA |
3 |
60 Cel |
||||||||
|
Carling Technologies |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
250 V |
50 V |
5 A |
QUICK CONNECT |
1000 A |
ROCKER |
19.31 mm |
19.31 inch |
SERIES TRIP |
38.99 mm |
CE; CUL; UL; VDE |
1 |
||||||||||||
Abb |
THERMAL MAGNETIC |
||||||||||||||||||||||||||
Defense Logistics Agency |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
120 V |
28 V |
1 A |
SCREW |
-55 Cel |
3500 A |
RATED BREAKING CAPACITY AT 28 VDC: 6000 A |
PUSH-PULL |
19.84 mm |
15.06 inch |
CORROSION RESISTANT; MOISTURE RESISTANT |
19.84mm x 15.06mm x 26.16mm |
TRIP FREE |
26.16 mm |
MIL-C-5809 |
1 |
121 Cel |
||||||||
Defense Logistics Agency |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
120 V |
28 V |
20 A |
SCREW |
-55 Cel |
2000 A |
RATED BREAKING CAPACITY AT 28 VDC: 6000 A |
PUSH-PULL |
19.84 mm |
15.06 inch |
CORROSION RESISTANT; MOISTURE RESISTANT |
19.84mm x 15.06mm x 26.16mm |
TRIP FREE |
26.16 mm |
MIL-C-5809 |
1 |
121 Cel |
||||||||
|
Siemens |
THERMAL MAGNETIC |
DIN-RAIL MOUNT |
690 V |
3.2 A |
SNAP ON |
-20 Cel |
10000 A |
INTERRUPTING CURRENT-MAX AT 450 VDC : 10000 A |
HANDLE |
97 mm |
45 inch |
IP20 |
97mm x 45mm x 96.9mm |
TRIP |
96.9 mm |
ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE |
3 |
60 Cel |
||||||||
|
TE Connectivity |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
250 V |
32 V |
12 A |
QUICK CONNECT |
1000 A |
2.2 Seconds |
PUSH TO RESET |
15.88 mm |
13.72 inch |
15.88mm x 13.72mm x 38.99mm |
SERIES TRIP |
38.99 mm |
CSA; UL; VDE |
1 |
||||||||||
TE Connectivity |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
250 V |
32 V |
12 A |
QUICK CONNECT |
2.2 Seconds |
PUSH TO RESET |
SERIES TRIP |
1 |
|||||||||||||||||
TE Connectivity |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
250 V |
32 V |
12 A |
QUICK CONNECT |
2.2 Seconds |
PUSH TO RESET |
SERIES TRIP |
1 |
|||||||||||||||||
|
Schneider Electric Sa |
THERMAL MAGNETIC CIRCUIT BREAKER |
DIN-RAIL MOUNT |
415 V |
16 A |
SNAP ON |
-25 Cel |
3000 A |
TOGGLE |
81 mm |
36 inch |
TRIP |
73 mm |
2 |
60 Cel |
||||||||||||
|
Siemens |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
690 V |
400 A |
SCREW |
-25 Cel |
55000 A |
TOGGLE |
248.92 mm |
137.16 inch |
IP40 |
248.92mm x 137.16mm x 109.22mm |
TRIP |
109.22 mm |
3 |
70 Cel |
||||||||||
|
Siemens |
THERMAL CIRCUIT BREAKER |
DIN RAIL |
400 V |
10 A |
SNAP ON |
-25 Cel |
5000 A |
5SY4110-7 |
ENVIRONMENTAL CHARACTERISTICS: IP20; SEALED |
89.8 mm |
17.6 inch |
ENVIRONMENT/MOISTURE RESISTANT |
89.8mm x 17.6mm x 70.2mm |
TRIP |
70.2 mm |
CE; EAC; IMQ; KTL; UL; VDE |
1 |
55 Cel |
||||||||
|
Eaton Corporation |
THERMAL MAGNETIC CIRCUIT BREAKER |
DIN RAIL |
480 V |
15 A |
SNAP ON |
-25 Cel |
14000 A |
TOGGLE |
105 mm |
35.3 inch |
TRIP FREE |
45 mm |
CSA; UL |
2 |
75 Cel |
|||||||||||
E-t-a Elektrotechnische Apparate |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
12 V |
10 A |
QUICK CONNECT |
-40 Cel |
150 A |
MODIFIED RESET |
13.3 mm |
7 inch |
CORROSION RESISTANT; IP00; IP50 |
TRIP |
25 mm |
1 |
85 Cel |
||||||||||||
Texas Instruments |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
120 V |
28 V |
20 A |
SCREW |
2000 A |
2TC2 |
PUSH/PULL |
19.84 mm |
15.06 inch |
CORROSSION RESISTANT |
19.84mm x 15.06mm x 26.16mm |
26.16 mm |
|||||||||||||
Abb |
THERMAL MAGNETIC |
||||||||||||||||||||||||||
|
TE Connectivity |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
240 V |
50 V |
5 A |
SCREW |
1000 A |
6 Seconds |
PUSH-PULL |
35.15 mm |
17.53 inch |
CORROSION/ENVIRONMENT/MOISTURE RESISTANT |
SERIES TRIP |
40.64 mm |
CSA; UL |
1 |
||||||||||
Eaton Corporation |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
120 V |
28 V |
10 A |
SCREW |
-55 Cel |
3500 A |
STANDARD: MIL-C-5809, RATED BREAKING CAPACITY AT 28 VDC: 6000 A |
PUSH BUTTON |
19.84 mm |
15.06 inch |
CORROSSION RESISTANT; MOISTURE RESISTANT |
19.84mm x 15.06mm x 26.16mm |
TRIP |
26.16 mm |
1 |
121 Cel |
|||||||||
Eaton Corporation |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
120 V |
28 V |
7.5 A |
SCREW |
-55 Cel |
3500 A |
STANDARD: MIL-C-5809, RATED BREAKING CAPACITY AT 28 VDC: 6000 A |
PUSH BUTTON |
19.84 mm |
15.06 inch |
CORROSSION RESISTANT; MOISTURE RESISTANT |
19.84mm x 15.06mm x 26.16mm |
TRIP |
26.16 mm |
1 |
121 Cel |
|||||||||
|
Phoenix Contact |
THERMAL MAGNETIC |
2800886 |
||||||||||||||||||||||||
Defense Logistics Agency |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
120 V |
28 V |
2 A |
SCREW |
-55 Cel |
2800 A |
RATED BREAKING CAPACITY AT 28 VDC: 6000 A |
PUSH-PULL |
19.84 mm |
15.06 inch |
CORROSION RESISTANT; MOISTURE RESISTANT |
19.84mm x 15.06mm x 26.16mm |
TRIP FREE |
26.16 mm |
MIL-C-5809 |
1 |
121 Cel |
||||||||
|
Schneider Electric Sa |
THERMAL MAGNETIC |
|||||||||||||||||||||||||
|
TE Connectivity |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
250 V |
50 V |
5 A |
QUICK CONNECT |
1000 A |
3 Seconds |
ROCKER |
48.01 mm |
24.89 inch |
SERIES TRIP |
43.79 mm |
2 |
||||||||||||
Texas Instruments |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
120 V |
28 V |
2 A |
SCREW |
2800 A |
2TC2 |
PUSH/PULL |
19.84 mm |
15.06 inch |
CORROSSION RESISTANT |
19.84mm x 15.06mm x 26.16mm |
26.16 mm |
|||||||||||||
|
Abb |
THERMAL MAGNETIC |
DIN RAIL |
277 V |
48 V |
10 A |
SCREW AND SNAP ON |
-25 Cel |
10000 A |
.2 Seconds |
BULK |
111 mm |
17.5 inch |
IP20; IP40 |
SHUNT TRIP |
69 mm |
CCC; CSA; EN; IEC; UL; VDE |
1 |
55 Cel |
INSTANTANEOUS |
|||||||
|
Phoenix Contact |
THERMAL MAGNETIC |
|||||||||||||||||||||||||
|
E-t-a Elektrotechnische Apparate |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
240 V |
50 V |
10 A |
QUICK CONNECT |
-30 Cel |
5000 A |
RATED BREAKING CAPACITY AT 50 VDC: 1000 A |
ROCKER |
CORROSION/MOISTURE RESISTANT; IP00; IP40 |
MANUAL ON/OFF |
CCC; CE; CSA; CQC; KTL; UL; VDE |
2 |
60 Cel |
|||||||||||
Carling Technologies |
MAGNETIC CIRCUIT BREAKER |
PANEL MOUNT |
80 V |
5 A |
SCREW |
-40 Cel |
7500 A |
HANDLE |
50.8 mm |
19.18 inch |
CORROSION/MOISTURE RESISTANT |
SERIES TRIP |
43.94 mm |
CSA; UL |
1 |
85 Cel |
|||||||||||
|
TE Connectivity |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
240 V |
50 V |
15 A |
SCREW |
1000 A |
6 Seconds |
TOGGLE |
35.15 mm |
17.53 inch |
CORROSION/ENVIRONMENT/MOISTURE RESISTANT |
SERIES TRIP |
40.64 mm |
CSA; UL |
1 |
||||||||||
Eaton Corporation |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
120 V |
28 V |
20 A |
SCREW |
-55 Cel |
3500 A |
STANDARD: MIL-C-5809, RATED BREAKING CAPACITY AT 28 VDC: 6000 A |
PUSH BUTTON |
19.84 mm |
15.06 inch |
CORROSSION RESISTANT; MOISTURE RESISTANT |
19.84mm x 15.06mm x 26.16mm |
TRIP |
26.16 mm |
1 |
121 Cel |
|||||||||
|
Abb |
THERMAL MAGNETIC |
|||||||||||||||||||||||||
|
Abb |
THERMAL MAGNETIC |
|||||||||||||||||||||||||
|
Schurter Ag |
THERMAL CIRCUIT BREAKER |
PANEL MOUNT |
240 V |
60 V |
20 A |
QUICK CONNECT |
-30 Cel |
2000 A |
ROCKER |
BULK |
36 mm |
29 inch |
IP40 |
TRIP FREE |
44.1 mm |
CCC; CSA; GB; IEC; UL; VDE |
2 |
60 Cel |
||||||||
|
Abb |
THERMAL MAGNETIC |
|||||||||||||||||||||||||
E-t-a Elektrotechnische Apparate |
THERMAL CIRCUIT BREAKER |
INLINE/HOLDER |
24 V |
5 A |
TAB/BLADE |
-40 Cel |
150 A |
PUSH TO RESET |
20 mm |
6 inch |
CORROSION/MOISTURE RESISTANT; IP00; IP30 |
TRIP FREE |
24 mm |
UL |
1 |
85 Cel |
|||||||||||
Carling Technologies |
MAGNETIC CIRCUIT BREAKER |
PANEL MOUNT |
250 V |
18 A |
SCREW |
-40 Cel |
3000 A |
HANDLE |
57.53 mm |
50.8 inch |
CORROSION/MOISTURE RESISTANT |
SERIES TRIP |
43.94 mm |
CSA; UL; VDE |
3 |
85 Cel |
|||||||||||
Schneider Electric Sa |
THERMAL MAGNETIC |
A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.
Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.
In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.