Circuit Breaker

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

S201-C16

Abb

THERMAL MAGNETIC

DIN RAIL

250 V

16 A

SNAP ON

-25 Cel

6000 A

TOGGLE

IP20; IP40

TRIP

CSA; IEC; UL

55 Cel

2TC2-5

Texas Instruments

THERMAL CIRCUIT BREAKER

PANEL MOUNT

120 V

28 V

5 A

SCREW

2500 A

2TC2

PUSH/PULL

19.84 mm

15.06 inch

CORROSSION RESISTANT

19.84mm x 15.06mm x 26.16mm

26.16 mm

XT3SU3150AFF000XXX

Abb

THERMAL MAGNETIC CIRCUIT BREAKER

DIN-RAIL MOUNT

347 V

500 V

150 A

SNAP ON

10000 A

MANUAL ON/OFF

CSA; UL

130 mm

76.2 inch

TRIP

70 mm

3

5SV3346-6

Siemens

EQUIPMENT LEAKAGE CIRCUIT BREAKER

DIN RAIL

400 V

63 A

SNAP ON

-25 Cel

10000 A

BULK

90 mm

72 inch

IP20

TRIP

70 mm

CCC; CE; CEBEC; EAC; IMQ; OVE; VDE

4

45 Cel

W28-XQ1A-1

TE Connectivity

THERMAL CIRCUIT BREAKER

PANEL MOUNT

250 V

32 V

1 A

QUICK CONNECT

1000 A

4.5 Seconds

PUSH TO RESET

15.88 mm

13.72 inch

15.88mm x 13.72mm x 38.99mm

SERIES TRIP

38.99 mm

CSA; UL; VDE

1

W67-X2Q12-20

TE Connectivity

MAGNETIC CIRCUIT BREAKER

PANEL MOUNT

277 V

20 A

QUICK CONNECT

-40 Cel

5000 A

2.2 Seconds

TOGGLE

50.8 mm

19.05 inch

FUNGUS RESISTANT; MOISTURE RESISTANT

50.8mm x 19.05mm x 41.66mm

SERIES TRIP

41.66 mm

CSA; UL

1

85 Cel

STANDARD

W67-X2Q1220

TE Connectivity

MAGNETIC CIRCUIT BREAKER

PANEL MOUNT

20 A

QUICK CONNECT

2.2 Seconds

TOGGLE

SERIES TRIP

1

18642

Schneider Electric Sa

THERMAL MAGNETIC

2909906

Phoenix Contact

THERMAL CIRCUIT BREAKER

S203-C16

Abb

THERMAL MAGNETIC

1610-21-30A

E-t-a Elektrotechnische Apparate

AC2-B2-26-610-144-C

Carling Technologies

MAGNETIC CIRCUIT BREAKER

PANEL MOUNT

277 V

10 A

QUICK CONNECT

-40 Cel

5000 A

STANDARDS: MIL-PRF-55629, MIL-STD-202

ROCKER

54.76 mm

38.48 inch

CORROSION/MOISTURE RESISTANT

SERIES TRIP

41.66 mm

CSA; UL

2

85 Cel

2CDS251001R0024

Abb

THERMAL MAGNETIC

S204M-D32

Abb

THERMAL MAGNETIC

MS132-10T

Abb

THERMAL CIRCUIT BREAKER

DIN-RAIL MOUNT

690 V

10 A

SCREW

-25 Cel

18000 A

ROTARY HANDLE

BULK

97.8 mm

45 inch

IP10; IP20

TRIP FREE

86.05 mm

EN; IEC

3

70 Cel

XT1NU3030AFF000XXX

Abb

THERMAL MAGNETIC CIRCUIT BREAKER

DIN-RAIL MOUNT

347 V

500 V

30 A

SNAP ON

18000 A

MANUAL ON/OFF

CSA; UL

130 mm

76.2 inch

TRIP

70 mm

3

2909909

Phoenix Contact

THERMAL CIRCUIT BREAKER

M9F52335

Schneider Electric Sa

THERMAL MAGNETIC

2CDS252001R0064

Abb

THERMAL MAGNETIC

CCP2-2-30CC

Eaton Corporation

EQUIPMENT LEAKAGE CIRCUIT BREAKER

PANEL MOUNT

600 V

125 V

30 A

200000 A

TOGGLE HANDLE

78.74 mm

35.56 inch

MANUAL ON/OFF

99.06 mm

UL

2

W58-XB1A4A-20

TE Connectivity

THERMAL CIRCUIT BREAKER

PANEL MOUNT

250 V

50 V

20 A

QUICK CONNECT

1000 A

6 Seconds

RATED BREAKING CAPACITY AT 50 VDC: 2000 A

PUSH TO RESET

34.93mm x 16.76mm x 34.93m

SERIES TRIP

1

5SV3346-6KL

Siemens

EQUIPMENT LEAKAGE CIRCUIT BREAKER

DIN-RAIL MOUNT

400 V

63 A

SCREW AND SNAP ON

10000 A

HANDLE

90 mm

72 inch

IP20

90mm x 72mm x 70mm

TRIP

70 mm

4

70 Cel

W58-XB1A4A-15

TE Connectivity

THERMAL CIRCUIT BREAKER

PANEL MOUNT

250 V

50 V

15 A

QUICK CONNECT

1000 A

6 Seconds

PUSH TO RESET

34.93 mm

16.76 inch

SERIES TRIP

34.93 mm

1

XT1NU3040AFF000XXX

Abb

THERMAL MAGNETIC

DIN-RAIL MOUNT

347 V

40 A

SNAP ON

18000 A

130 mm

76.2 inch

130mm x 76.2mm x 70mm

TRIP

70 mm

CSA; UL

3

QOB250GFI

Schneider Electric Sa

THERMAL MAGNETIC

QOB250H

Schneider Electric Sa

THERMAL CIRCUIT BREAKER

QOB250VH

Schneider Electric Sa

THERMAL MAGNETIC

QOB250VH1021

Schneider Electric Sa

THERMAL MAGNETIC

W23-X1A1G-50

TE Connectivity

THERMAL CIRCUIT BREAKER

PANEL MOUNT

240 V

50 V

50 A

SCREW

1000 A

6 Seconds

PUSH-PULL

35.15 mm

17.53 inch

CORROSION/ENVIRONMENT/MOISTURE RESISTANT

SERIES TRIP

40.64 mm

CSA; UL

1

MS3320-15V

Eaton Corporation

THERMAL CIRCUIT BREAKER

PANEL MOUNT

120 V

28 V

15 A

SCREW

-55 Cel

3500 A

STANDARD: MIL-C-5809, RATED BREAKING CAPACITY AT 28 VDC: 6000 A

PUSH BUTTON

19.84 mm

15.06 inch

CORROSSION RESISTANT; MOISTURE RESISTANT

19.84mm x 15.06mm x 26.16mm

TRIP

26.16 mm

1

121 Cel

2TC2-21/2

Texas Instruments

THERMAL CIRCUIT BREAKER

PANEL MOUNT

120 V

28 V

2.5 A

SCREW

2800 A

2TC2

PUSH/PULL

19.84 mm

15.06 inch

CORROSSION RESISTANT

19.84mm x 15.06mm x 26.16mm

26.16 mm

W31-X2M1G-10

TE Connectivity

THERMAL CIRCUIT BREAKER

PANEL MOUNT

240 V

50 V

10 A

SCREW

1000 A

6 Seconds

TOGGLE

35.15 mm

17.53 inch

CORROSION/ENVIRONMENT/MOISTURE RESISTANT

SERIES TRIP

40.64 mm

CSA; UL

1

QOB250EPD

Schneider Electric Sa

THERMAL CIRCUIT BREAKER

236404

Eaton Corporation

THERMAL CIRCUIT BREAKER

PANEL MOUNT

400 V

40 A

SCREW

-25 Cel

10000 A

IP20

TRIP

3

75 Cel

QOB2501021

Schneider Electric Sa

THERMAL MAGNETIC

W28-XQ1A-6

TE Connectivity

THERMAL CIRCUIT BREAKER

PANEL MOUNT

250 V

32 V

6 A

QUICK CONNECT

1000 A

2.2 Seconds

PUSH TO RESET

15.88 mm

13.72 inch

15.88mm x 13.72mm x 38.99mm

SERIES TRIP

38.99 mm

CSA; UL; VDE

1

S202M-C6

Abb

THERMAL MAGNETIC

W92-X112-30

TE Connectivity

MAGNETIC CIRCUIT BREAKER

PANEL MOUNT

277 V

30 A

STUD

-40 Cel

5000 A

2.2 Seconds

TOGGLE

63.5 mm

38.1 inch

MOISTURE RESISTANT

SERIES TRIP

50.42 mm

CSA; UL; VDE

2

85 Cel

STANDARD

185120F-011

Eaton Corporation

THERMAL CIRCUIT BREAKER

PANEL MOUNT

30 V

120 A

SCREW

-32 Cel

LEVER

73.41 mm

48.26 inch

TRIP

36.58 mm

SAE; UL

1

82 Cel

S201-B13

Abb

THERMAL MAGNETIC

2TC2-3

Texas Instruments

THERMAL CIRCUIT BREAKER

PANEL MOUNT

120 V

28 V

3 A

SCREW

2500 A

2TC2

PUSH/PULL

19.84 mm

15.06 inch

CORROSSION RESISTANT

19.84mm x 15.06mm x 26.16mm

26.16 mm

2CDS251001R0427

Abb

THERMAL MAGNETIC

SU202M-Z5

Abb

THERMAL MAGNETIC

QOB250

Schneider Electric Sa

THERMAL CIRCUIT BREAKER

QOB250HID

Schneider Electric Sa

THERMAL CIRCUIT BREAKER

S203-B20

Abb

THERMAL MAGNETIC

3RV2041-4JA15

Siemens

THERMAL MAGNETIC

DIN-RAIL MOUNT

690 V

63 A

SCREW AND SNAP ON

-20 Cel

3000 A

ROTARY HANDLE

165 mm

70 inch

IP00; IP20

165mm x 70mm x 176mm

TRIP

176 mm

3

60 Cel

4411.0017

Schurter Ag

THERMAL CIRCUIT BREAKER

PANEL MOUNT

277 V

28 V

30 A

QUICK CONNECT

-5 Cel

1000 A

RESET TYPE

BULK

31 mm

11.5 inch

IP40

TRIP FREE

45 mm

CCC; CSA; GB; IEC; UL; VDE

1

60 Cel

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.