EMI Mains Filters

Reset All
Part RoHS Manufacturer Filter Type Maximum DC Resistance Maximum Frequency Rated Current Minimum Insulation Resistance Approvals (V) Insertion Loss At Minimum Frequency No. of Functions Screening Level High Pot Maximum Leakage Current Packing Method Mounting Type Rated Voltage No. of Terminals Sub-Category Dimensions Maximum Operating Temperature Insertion Loss At Maximum Frequency Package Material Minimum Operating Temperature Terminal Finish Inductance Manufacturer Series Height Width (mm) Diameter (mm) Additional Features JESD-609 Code Minimum Frequency Operating Frequency (Hz) Length

SN8D-500

KEMET Corporation

SINGLE PHASE EMI FILTER

2 A

BULK

THROUGH HOLE MOUNT

105 Cel

-25 Cel

13 mm

17

SS11V-R10093-CH

KEMET Corporation

SINGLE PHASE EMI FILTER

1 A

100 Mohm

500 V

THROUGH HOLE MOUNT

250 V

L22.0XB14.5XH21.5 (mm)/L0.866XB0.571XH0.846 (inch)

120 Cel

-25 Cel

21.5 mm

14.5

22 mm

SS21V-R300013

KEMET Corporation

SINGLE PHASE EMI FILTER

3 A

100 Mohm

UL

500 V

TRAY

THROUGH HOLE MOUNT

250 V

L20.6XB16.8XH24.5 (mm)/L0.811XB0.661XH0.965 (inch)

120 Cel

-25 Cel

24.5 mm

16.8

20.6 mm

SS30V-400021

KEMET Corporation

SINGLE PHASE EMI FILTER

4 A

100 Mohm

UL

500 V

TRAY

THROUGH HOLE MOUNT

250 V

120 Cel

-25 Cel

33 mm

22.5

31 mm

SSB11V-R17043

KEMET Corporation

SINGLE PHASE EMI FILTER

1.7 A

TRAY

THROUGH HOLE MOUNT

250 V

L22.0XB14.5XH21.5 (mm)/L0.866XB0.571XH0.846 (inch)

130 Cel

-25 Cel

21.5 mm

14.5

22 mm

SSHB21H-R30050

KEMET Corporation

SINGLE PHASE EMI FILTER

3 A

100 Mohm

UL

500 V

TRAY

THROUGH HOLE MOUNT

250 V

130 Cel

-25 Cel

15.5 mm

23

26 mm

SSHB21HS-R10300

KEMET Corporation

SINGLE PHASE EMI FILTER

1 A

100 Mohm

UL

500 V

TRAY

THROUGH HOLE MOUNT

250 V

120 Cel

-25 Cel

15.5 mm

23

26 mm

SSR10H-10170

KEMET Corporation

SINGLE PHASE EMI FILTER

1 A

100 Mohm

UL

500 V

TRAY

THROUGH HOLE MOUNT

250 V

120 Cel

-25 Cel

21 mm

13

23.5 mm

SSR10V-07330

KEMET Corporation

SINGLE PHASE EMI FILTER

.7 A

100 Mohm

UL

500 V

TRAY

THROUGH HOLE MOUNT

250 V

120 Cel

-25 Cel

13.5 mm

18

22 mm

SSR21NV-M18164

KEMET Corporation

SINGLE PHASE EMI FILTER

1.8 A

100 Mohm

UL

500 V

TRAY

THROUGH HOLE MOUNT

250 V

L22.0XB16.0XH27.0 (mm)/L0.866XB0.63XH1.063 (inch)

120 Cel

-25 Cel

27 mm

16

22 mm

SSRH24NH-30145

KEMET Corporation

SINGLE PHASE EMI FILTER

3 A

100 Mohm

UL

TRAY

THROUGH HOLE MOUNT

250 V

120 Cel

-25 Cel

18 mm

25.5

25.5 mm

SSRH24NH-50041

KEMET Corporation

SINGLE PHASE EMI FILTER

5 A

100 Mohm

UL

TRAY

THROUGH HOLE MOUNT

250 V

120 Cel

-25 Cel

18 mm

25.5

25.5 mm

SSRH24NVS-40059

KEMET Corporation

SINGLE PHASE EMI FILTER

4 A

100 Mohm

UL

TRAY

THROUGH HOLE MOUNT

250 V

120 Cel

-25 Cel

31 mm

20

25.5 mm

SSRH7H-M04596

KEMET Corporation

SINGLE PHASE EMI FILTER

.4 A

100 Mohm

UL

TRAY

THROUGH HOLE MOUNT

250 V

120 Cel

-25 Cel

12 mm

14.5

18 mm

SSRH7HS-M05324

KEMET Corporation

SINGLE PHASE EMI FILTER

.5 A

100 Mohm

UL

TRAY

THROUGH HOLE MOUNT

250 V

120 Cel

-25 Cel

12 mm

14.5

18 mm

SU9VF-03060

KEMET Corporation

SINGLE PHASE FILTER

.3 A

TRAY

THROUGH HOLE MOUNT

250 V

120 Cel

-25 Cel

17 mm

11

17 mm

AFH461

Infineon Technologies

SINGLE PHASE EMI FILTER

3 A

38535Q/M;38534H;883B

PANEL MOUNT

50 V

5

Data Line Filters

125 Cel

METAL

-55 Cel

.325 mm

1.12

1.45 mm

AFH461/EM

Infineon Technologies

SINGLE PHASE EMI FILTER

5

Data Line Filters

125 Cel

METAL

-55 Cel

NEF1-3-2794110

Phoenix Contact

SINGLE PHASE EMI FILTER

3 A

UL; IEC; VDE

PANEL MOUNT

264 V

100 Cel

-25 Cel

79.4 mm

25

60Hz

84.2 mm

NEF1-10-2788977

Phoenix Contact

SINGLE PHASE EMI FILTER

10 A

UL; IEC; VDE

PANEL MOUNT

250 V

100 Cel

-25 Cel

79.4 mm

40

84.1 mm

FIL-1S-1-6A-230AC-UT

Phoenix Contact

SINGLE PHASE EMI FILTER

6 A

IEC; UL; VDE

PANEL MOUNT

230 V

99 mm

45

99.5 mm

FIL-1S-1-1A-230AC-UT

Phoenix Contact

SINGLE PHASE EMI FILTER

1 A

IEC; UL; VDE

PANEL MOUNT

230 V

99 mm

27

99.5 mm

FIL-1S-1-20A-230AC-UT

Phoenix Contact

SINGLE PHASE EMI FILTER

20 A

IEC; UL; VDE

PANEL MOUNT

230 V

99 mm

45

99.5 mm

FIL-1S-1-10A-230AC-PT

Phoenix Contact

SINGLE PHASE EMI FILTER

10 A

IEC; UL; VDE

PANEL MOUNT

230 V

99 mm

45

99.5 mm

FIL-1S-1-3A-230AC-PT

Phoenix Contact

SINGLE PHASE EMI FILTER

3 A

IEC; UL; VDE

PANEL MOUNT

230 V

99 mm

27

99.5 mm

FIL-1S-1-6A-230AC-PT

Phoenix Contact

SINGLE PHASE EMI FILTER

6 A

IEC; UL; VDE

PANEL MOUNT

230 V

99 mm

45

99.5 mm

FIL-1S-1-3A-230AC-UT

Phoenix Contact

SINGLE PHASE EMI FILTER

3 A

IEC; UL; VDE

PANEL MOUNT

230 V

99 mm

27

99.5 mm

FIL-1S-1-1A-230AC-PT

Phoenix Contact

SINGLE PHASE EMI FILTER

1 A

IEC; UL; VDE

PANEL MOUNT

230 V

99 mm

27

99.5 mm

FIL-1S-1-10A-230AC-UT

Phoenix Contact

SINGLE PHASE EMI FILTER

10 A

IEC; UL; VDE

PANEL MOUNT

230 V

99 mm

45

99.5 mm

FIL-1S-1-20A-230AC-PT

Phoenix Contact

SINGLE PHASE EMI FILTER

20 A

IEC; UL; VDE

PANEL MOUNT

230 V

99 mm

45

99.5 mm

S8V-NFS203

Omron

SINGLE PHASE EMI FILTER

3 A

100 Mohm

EN; CSA; IEC; UL

1 mA

PANEL MOUNT

250 V

85 Cel

-40 Cel

90 mm

32

50/60Hz

90 mm

S8V-NFS206

Omron

SINGLE PHASE EMI FILTER

6 A

100 Mohm

EN; CSA; IEC; UL

1 mA

PANEL MOUNT

250 V

85 Cel

-40 Cel

90 mm

32

50/60Hz

90 mm

EMI Mains Filters

EMI mains filters are electronic filters that are used to suppress electromagnetic interference (EMI) from mains power lines. They are designed to provide a high level of attenuation of unwanted frequencies while allowing the desired power signal to pass through with minimal distortion.

EMI mains filters use a combination of passive and active components, including capacitors, inductors, resistors, and diodes, to filter out noise and interference from power lines. They can be designed for a wide range of power ratings and frequencies, depending on the application.

EMI mains filters can be designed as low-pass filters, which allow low-frequency power signals to pass through while attenuating high-frequency EMI signals, or as band-stop filters, which block a specific range of frequencies while allowing other frequencies to pass through. They can also be designed with multiple stages of filtering to provide increased attenuation of unwanted frequencies.

EMI mains filters are commonly used in a variety of electronic systems, including power supplies, motor drives, medical equipment, and industrial control systems. They are also used in residential and commercial buildings to suppress EMI noise from power lines and prevent interference with other electronic devices.