Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

KTK-R-15

Eaton Corporation

ELECTRIC FUSE

INLINE/HOLDER

600 V

15 A

END CAP

NICKEL

200000 A

BOX

10.3 mm

CC

600 V

10.3mm x 38.1mm

38.1 mm

CE; CSA; UL

FAST

0451001.MRL

Littelfuse

ELECTRIC FUSE

SURFACE MOUNT

125 V

125 V

1 A

WRAPAROUND

.6029 J

-55 Cel

GOLD

50 A

5 Seconds

TR

6.1 mm

2.69 inch

e4

125 V

NANO

6.1mm x 2.69mm x 2.69mm

2.69 mm

CE; CSA; CUL; PSE; TUV; UL

125 Cel

VERY FAST

0458001.DR

Littelfuse

ELECTRIC FUSE

SURFACE MOUNT

48 V

75 V

1 A

WRAPAROUND

.168 J

-55 Cel

GOLD

50 A

5 Seconds

0.16

TR

3.175 mm

1.575 inch

e4

75 V

NANO

3.175mm x 1.575mm x 1.575mm

1.575 mm

CUL; UL

125 Cel

045801.5DR

Littelfuse

ELECTRIC FUSE

SURFACE MOUNT

48 V

75 V

1.5 A

WRAPAROUND

.548 J

-55 Cel

GOLD

50 A

5 Seconds

0.54

TR

3.175 mm

1.575 inch

e4

75 V

NANO

3.175mm x 1.575mm x 1.575mm

1.575 mm

CUL; UL

125 Cel

FNA-10

Eaton Corporation

ELECTRIC FUSE

INLINE/HOLDER

125 V

10 A

END CAP

Silver (Ag)

10000 A

10.31 mm

e4

125 V

10.31mm x 38.1mm

38.1 mm

CSA, UL

TIME LAG

FNQ-R-10

Eaton Corporation

ELECTRIC FUSE

INLINE/HOLDER

600 V

10 A

END CAP

Nickel (Ni)

200000 A

BOX

10.3 mm

CC

600 V

10.3mm x 38.1mm

38.1 mm

CE; CSA; UL

TIME DELAY

0685T5000-01

Bel Fuse

ELECTRIC FUSE

SURFACE MOUNT

63 V

63 V

5 A

WRAPAROUND

5.3 J

-55 Cel

TIN OVER NICKEL

50 A

.002 Seconds

TR, 7 INCH

3.2 mm

1.58 inch

e3

63 V

1206

.63 mm

AEC-Q200; TUV; UL

125 Cel

SLOW

0217005.MXP

Littelfuse

ELECTRIC FUSE

INLINE/HOLDER

250 V

60 V

5 A

END CAP

42.795 J

-55 Cel

NICKEL

50 A

.01 Seconds

BULK

5.2 mm

250 V

5x20mm

5.2mm x 20mm

20 mm

BSI; CCC; CE; CSA; IEC; KC; PSE; SEMKO; UL; VDE

125 Cel

VERY FAST

02170.05MXP

Littelfuse

ELECTRIC FUSE

INLINE/HOLDER

250 V

.05 A

END CAP

.00049 J

-55 Cel

35 A

.003 Seconds

PRE ARCHING TIME: OPEN WITHIN 3 MILLISEC AT 400% RATED CURRENT

BULK

5.2 mm

250 V

5x20mm

20 mm

CCC; CE; CSA; CUL; KC; SEMKO; UL; VDE

125 Cel

FAST

0458004.DR

Littelfuse

ELECTRIC FUSE

SURFACE MOUNT

32 V

75 V

4 A

WRAPAROUND

4.832 J

-55 Cel

GOLD

50 A

5 Seconds

4.8

TR

3.175 mm

1.575 inch

e4

75 V

NANO

3.175mm x 1.575mm x 1.575mm

1.575 mm

CUL; UL

125 Cel

04611.25ER

Littelfuse

ELECTRIC FUSE

SURFACE MOUNT

600 V

80 V

1.25 A

WRAPAROUND

16.5 J

-55 Cel

SILVER

60 A

1 Seconds

RATED BREAKING CAPACITY AT 80 VDC: 100 A

16.5

TR

10.1 mm

3.12 inch

e4

600 V

4012

10.1mm x 3.12mm x 3.12mm

3.12 mm

CSA; UL

125 Cel

SLOW

0452001.MRL

Littelfuse

ELECTRIC FUSE

SURFACE MOUNT

125 V

125 V

1 A

WRAPAROUND

1.98 J

-55 Cel

GOLD

50 A

.002 Seconds

1.98

TR

6.1 mm

2.69 inch

e4

125 V

NANO

6.1mm x 2.69mm x 2.69mm

2.69 mm

CSA; CUL; UL

125 Cel

SLOW

3413.0330.22

Schurter Ag

ELECTRIC FUSE

SURFACE MOUNT

32 V

63 V

15 A

WRAPAROUND

65 J

-55 Cel

TIN

100 A

65

TR, 7 INCH

3.2 mm

1.6 inch

e3

1 ms

3.2x1.6mm

3.2mm x 1.6mm x 0.6mm

.6 mm

CUL; UL

90 Cel

TIME LAG

04661.25NR

Littelfuse

ELECTRIC FUSE

SURFACE MOUNT

63 V

63 V

1.25 A

END CAP

.064 J

-55 Cel

MATTE TIN OVER NICKEL

50 A

RATED BREAKING CAPACITY AT 63 VDC: 50 A

TAPE AND REEL

3.18 mm

1.52 inch

e3

3.18mm x 1.52mm x 0.58mm

.58 mm

CSA; UL

90 Cel

VERY FAST

0466.125NR

Littelfuse

ELECTRIC FUSE

SURFACE MOUNT

125 V

125 V

.125 A

WRAPAROUND

.0004 J

-55 Cel

MATTE TIN OVER NICKEL

50 A

.2 Seconds

PRE ARCING TIME: OPEN WITHIN 0.2 SEC AT 300% RATED CURRENT

0.0004

TR

3.18 mm

1.52 inch

e3

125 V

1206

3.18mm x 1.52mm x 0.58mm

.58 mm

CSA; UL

90 Cel

VERY FAST

FNQ-R-15

Eaton Corporation

ELECTRIC FUSE

INLINE/HOLDER

600 V

300 V

15 A

END CAP

Nickel (Ni)

200000 A

RATED BREAKING CAPACITY AT 300 VDC: 10000 A

BOX

10.3 mm

CC

600 V

10.3mm x 38.1mm

38.1 mm

CE; CSA; UL

TIME DELAY

LP-CC-20

Eaton Corporation

ELECTRIC FUSE

INLINE/HOLDER

600 V

300 V

20 A

END CAP

200000 A

RATED BREAKING CAPACITY AT 300 VDC: 20000 A

BOX

10 mm

600 V

10.3mm x 38.1mm

38 mm

CE; CSA; UL

TIME DELAY

0458007.DR

Littelfuse

ELECTRIC FUSE

SURFACE MOUNT

32 V

63 V

7 A

WRAPAROUND

20.48 J

-55 Cel

GOLD

50 A

5 Seconds

20.4

TR

3.175 mm

1.575 inch

e4

63 V

NANO

3.175mm x 1.575mm x 1.575mm

1.575 mm

CUL; UL

125 Cel

37211000411

Littelfuse

ELECTRIC FUSE

THROUGH HOLE

250 V

1 A

PIN WIRE

7.5 J

-40 Cel

MATTE TIN

35 A

.02 Seconds

5.5

BULK

8.5 mm

e3

250 V

TR5

8.5mm x 8mm

8 mm

CCC; CE; CUL; KC; PSE; UL; VDE

85 Cel

TIME LAG

0297002WXNV

Littelfuse

ELECTRIC FUSE

INLINE/HOLDER

32 V

2 A

TAB/BLADE

2.8 J

-40 Cel

SILVER

RATED BREAKING CAPACITY AT 32 VDC: 1000A

10.9 mm

3.8 inch

e4

10.9mm x 3.8mm x 8.8mm

8.8 mm

125 Cel

0297002.WXNV

Littelfuse

ELECTRIC FUSE

INLINE/HOLDER

32 V

2 A

TAB/BLADE

9 J

-40 Cel

SILVER

1000 A

.03 Seconds

2.8

10.9 mm

3.8 inch

e4

32 V

MINI

10.9mm x 3.8mm x 8.8mm

8.8 mm

UL

125 Cel

0297004.WXNV

Littelfuse

ELECTRIC FUSE

INLINE/HOLDER

32 V

4 A

TAB/BLADE

31 J

-40 Cel

Silver (Ag)

1000 A

.03 Seconds

17

10.9 mm

3.8 inch

e4

32 V

MINI

10.9mm x 3.8mm x 8.8mm

8.8 mm

UL

125 Cel

0297004WXNV

Littelfuse

ELECTRIC FUSE

INLINE/HOLDER

32 V

4 A

TAB/BLADE

17 J

-40 Cel

SILVER

RATED BREAKING CAPACITY AT 32 VDC: 1000A

10.9 mm

3.8 inch

e4

10.9mm x 3.8mm x 8.8mm

8.8 mm

125 Cel

17.5TDLSJ16

Eaton Corporation

ELECTRIC FUSE

INLINE/HOLDER

17500 V

17500 V

16 A

END CAP

290 J

50000 A

51 mm

INDICATOR

51mm x 292mm

292 mm

DIN 43625; IEC

JJS-50

Eaton Corporation

ELECTRIC FUSE

INLINE/HOLDER

600 V

50 A

END CAP

200000 A

20.6 mm

20.6mm x 39.7mm

39.7 mm

CE; CSA; UL

VERY FAST

LP-CC-25

Eaton Corporation

ELECTRIC FUSE

INLINE/HOLDER

600 V

300 V

25 A

END CAP

200000 A

RATED BREAKING CAPACITY AT 300 VDC: 20000 A

BOX

10 mm

10.3mm x 38.1mm

38 mm

CE; CSA; UL

TIME DELAY

0451005.MRL

Littelfuse

ELECTRIC FUSE

SURFACE MOUNT

125 V

125 V

5 A

WRAPAROUND

5.566 J

-55 Cel

GOLD

50 A

5 Seconds

TR

6.1 mm

2.69 inch

e4

125 V

NANO

6.1mm x 2.69mm x 2.69mm

2.69 mm

CE; CSA; CUL; PSE; TUV; UL

125 Cel

VERY FAST

236.100

Littelfuse

ELECTRIC FUSE

THROUGH HOLE

250 V

.1 A

PIN WIRE

.0016 J

236

5.25 mm

5.25mm x 22.5mm

22.5 mm

CSA; UL

FAST

045802.5DR

Littelfuse

ELECTRIC FUSE

SURFACE MOUNT

48 V

75 V

2.5 A

WRAPAROUND

1.408 J

-55 Cel

GOLD

50 A

5 Seconds

1.4

TR

3.175 mm

1.575 inch

e4

48 V

NANO

3.175mm x 1.575mm x 1.575mm

1.575 mm

CUL; UL

125 Cel

80ET

Eaton Corporation

ELECTRIC FUSE

INLINE/HOLDER

690 V

350 V

80 A

TAB/BLADE

360 J

200000 A

RATED BREAKING CAPACITY AT 690 VDC: 200000 A

BOX

48 mm

690 V

48mm x 19.1mm

19.1 mm

BS 88; CE

0468001.NRHF

Littelfuse

ELECTRIC FUSE

SURFACE MOUNT

63 V

63 V

1 A

WRAPAROUND

.127 J

-55 Cel

MATTE TIN

50 A

.0015 Seconds

PRE ARCING TIME: OPEN WITHIN 1.5 MILLISEC AT 800% RATED CURRENT

0.127

TR

3.18 mm

1.52 inch

e3

63 V

1206

3.18mm x 1.52mm x 0.58mm

.635 mm

CSA; CUL; UL

90 Cel

TIME DELAY

0218002.MXP

Littelfuse

ELECTRIC FUSE

INLINE/HOLDER

250 V

2 A

END CAP

14.45 J

-55 Cel

NICKEL

35 A

.02 Seconds

14.45

BULK

5.2 mm

250 V

5x20mm

5.2mm x 20mm

20 mm

CCC; CE; CSA; KC; PSE; SEMKO; SEV; UL; VDE

125 Cel

TIME LAG

DMM-B-11A

Eaton Corporation

ELECTRIC FUSE

INLINE/HOLDER

1000 V

1000 V

11 A

END CAP

Nickel (Ni)

20000 A

RATED BREAKING CAPACITY AT 1000 VDC: 20000 A

BOX

10 mm

10mm x 38.1mm

38.1 mm

UL

FAST

3413.0328.22

Schurter Ag

ELECTRIC FUSE

SURFACE MOUNT

32 V

63 V

10 A

WRAPAROUND

21 J

-55 Cel

TIN

100 A

21

TR, 7 INCH

3.2 mm

1.6 inch

e3

1 ms

3.2x1.6mm

3.2mm x 1.6mm x 0.6mm

.6 mm

CUL; UL

90 Cel

TIME LAG

ATQR25

Mersen S A

ELECTRIC FUSE

INLINE/HOLDER

600 V

300 V

25 A

END CAP

200000 A

RATED BREAKING CAPACITY AT 300 VDC: 100000 A

10.4 mm

10.4mm x 38.1mm

38.1 mm

CSA, CE, UL

80 Cel

TIME DELAY

LPJ-70SP

Eaton Corporation

ELECTRIC FUSE

INLINE/HOLDER

600 V

300 V

70 A

TAB/BLADE

300000 A

RATED BREAKING CAPACITY AT 300 VDC: 100000 A

28.6 mm

J

600 V

28.6mm x 66.7mm

66.7 mm

CE; CSA; UL

TIME DELAY

36913150000

Littelfuse

ELECTRIC FUSE

THROUGH HOLE

300 V

300 V

3.15 A

PIN WIRE

78.388 J

-40 Cel

MATTE TIN

50 A

20 Seconds

55

AMMO PACK

8.5 mm

4 inch

e3

300 V

TE5

8.5mm x 4mm x 8mm

8 mm

CUL; PSE; UL; VDE

85 Cel

TIME LAG

FNQ-R-1/4

Eaton Corporation

ELECTRIC FUSE

INLINE/HOLDER

600 V

.25 A

END CAP

Nickel (Ni)

200000 A

BOX

10.3 mm

CC

600 V

10.3mm x 38.1mm

38.1 mm

CE; CSA; UL

TIME DELAY

0216002MXP

Littelfuse

ELECTRIC FUSE

INLINE/HOLDER

250 V

250 V

2 A

END CAP

1.87 J

-55 Cel

TIN

1500 A

.01 Seconds

BULK

5.2 mm

e3

5x20mm

20 mm

CCC, CE, CSA, PSE, UL, VDE

125 Cel

FAST

0216002.MXP

Littelfuse

ELECTRIC FUSE

INLINE/HOLDER

250 V

2 A

END CAP

1.87 J

-55 Cel

NICKEL

1500 A

.02 Seconds

1.87

BULK

5.2 mm

250 V

5x20mm

5.2mm x 20mm

20 mm

CCC; CE; CSA; IEC; KC; PSE; SEMKO; SEV; UL; VDE

125 Cel

FAST

ATDR15

Mersen S A

ELECTRIC FUSE

INLINE/HOLDER

600 V

300 V

15 A

END CAP

200000 A

RATED BREAKING CAPACITY AT 300 VDC: 100000 A

10.4 mm

10.4mm x 38.1mm

38.1 mm

CSA; UL

TIME DELAY

0437001.WR

Littelfuse

ELECTRIC FUSE

SURFACE MOUNT

63 V

63 V

1 A

WRAPAROUND

.1 J

-55 Cel

TIN OVER NICKEL

50 A

1 Seconds

0.1

TR

3.2 mm

1.63 inch

e3

63 V

1206

3.2mm x 1.63mm x 0.82mm

.835 mm

CSA; CUL; UL

150 Cel

FAST

39211000000

Littelfuse

ELECTRIC FUSE

THROUGH HOLE

250 V

1 A

PIN WIRE

8 J

-40 Cel

MATTE TIN

35 A

.02 Seconds

5.8

AMMO PACK; TAPE

8.5 mm

4 inch

e3

250 V

TE5

8.5mm x 4mm x 8mm

8 mm

CCC; CE; CUL; KC; PSE; VDE; UL

125 Cel

TIME LAG

ATM10

Mersen S A

ELECTRIC FUSE

INLINE/HOLDER

600 V

600 V

10 A

END CAP

100000 A

RATED BREAKING CAPACITY = 13.5A-100KA

BULK

10 mm

600 V

MIDGET

10mm x 38mm

38 mm

CSA; UL

FAST

ATM-10

Eaton Corporation

ELECTRIC FUSE

INLINE/HOLDER

32 V

10 A

TAB/BLADE

-40 Cel

Silver (Ag)

1000 A

RATED BREAKING CAPACITY AT 32 VDC: 1000 A

BOX

10.92 mm

3.81 inch

e4

32 V

10.92mm x 3.81mm x 8.81mm

8.81 mm

UL

100 Cel

FAST

0257010PXPV

Littelfuse

ELECTRIC FUSE

INLINE/HOLDER

32 V

10 A

TAB/BLADE

115 J

-40 Cel

Tin (Sn)

1000 A

0257

RATED BREAKING CAPACITY AT 32 VDC: 1000A

BULK

19.05 mm

5.08 inch

e3

19.05mm x 5.08mm x 12.19mm

12.19 mm

UL

105 Cel

0257010.PXPV

Littelfuse

ELECTRIC FUSE

INLINE/HOLDER

32 V

10 A

TAB/BLADE

115 J

-40 Cel

Tin/Copper (Sn/Cu)

1000 A

360000 Seconds

115

BULK

19.05 mm

5.08 inch

ATO

e2

32 V

19.05mm x 5.08mm x 12.19mm

12.19 mm

UL

105 Cel

FAST

LPJ-125SPI

Eaton Corporation

ELECTRIC FUSE

INLINE/HOLDER

600 V

300 V

125 A

TAB/BLADE

300000 A

RATED BREAKING CAPACITY AT 300 VDC: 100000 A

BOX

41.4 mm

J

600 V

INDICATOR

41.4mm x 76.2mm

76.2 mm

CE; CSA; UL

TIME DELAY

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.